L1 Operator Lab Exercises
Five practical exercises required before sitting the L1 written exam. Each exercise requires assessor presence and sign-off. Use a training unit, not production fleet hardware.
Lab 1: Pre-Deployment Visual Inspection — Unitree G1
Objective: Perform a complete pre-deployment visual inspection on a Unitree G1 and produce a compliant TechMedix log entry.
Equipment Required:
- Unitree G1 training unit (powered off, battery installed)
- TechMedix technician account
- Flashlight (min 200 lumen)
- Inspection checklist (printout from platform module)
- Camera or phone for documentation photos
Safety Prerequisites:
- Confirm robot is in LOTO state: hardware E-stop pressed, battery connector verified disconnected
- Don nitrile gloves before handling any robot surfaces
- Assessor must be present within 3 meters throughout
Procedure:
- Receive the robot in an unknown pre-service state (assessor will configure 2-3 intentional defects).
- Begin at the head: inspect camera lenses for contamination or scratches. Photograph findings.
- Move to the torso: inspect panel fasteners (all 8 visible), cable routing at shoulder junctions. Record any loose fasteners by position.
- Inspect right arm from shoulder to end-effector: check joint housings for cracks, grease seepage at harmonic drive seals. Manually articulate elbow and wrist (powered off) and note any grinding or catching.
- Repeat for left arm.
- Inspect both legs from hip to ankle: check knee joint for play by firmly grasping above and below the knee and testing for perpendicular rocking. Record any play in degrees (estimate; use a degree reference card if available).
- Inspect battery compartment seal (do not remove battery if it was not part of the scope — note seal condition only).
- Photograph: one full front view, one full rear view, one close-up of each defect found.
- Log findings in TechMedix using the correct work order format.
- Present work order to assessor before submitting.
Expected Outcomes:
- All intentional defects identified and documented
- Zero false-positive findings (assessor will verify)
- TechMedix log entry complete with photos and all required fields
Common Errors:
- Skipping the torso-to-shoulder cable inspection (most technicians rush past this)
- Logging subjective cause rather than objective finding ("bearing worn" vs "grinding felt in elbow joint during manual articulation")
- Missing the battery compartment seal in the inspection sequence
Assessor Sign-off Criteria: All intentional defects found. Log entry accepted (no fields missing). Safety procedure followed throughout (no approach within 2m of powered robot, LOTO verified at start).
Lab 2: Battery Swap and SoH Check — DJI Agras T50
Objective: Safely swap a DJI Agras T50 agriculture drone battery and perform and log a SoH assessment.
Equipment Required:
- DJI Agras T50 training unit (disarmed)
- Replacement battery (training battery, partially discharged)
- DJI battery tester or multimeter (CAT III, 600V rated)
- Anti-static work mat
- LiPo-safe storage bag
- TechMedix account
Safety Prerequisites:
- Motors must be confirmed disarmed (DJI app shows DISARMED state)
- Maintain 3-meter clearance from propellers throughout
- No open flames or hot surfaces within 5 meters
- Assessor present throughout
Procedure:
- Confirm drone is disarmed. Open DJI Pilot 2 and verify Motors DISARMED status. Do not proceed until confirmed.
- Press battery release and slide the battery pack out of the T50 battery bay. Note battery orientation before removal.
- Place removed battery on anti-static mat. Do not set on concrete or bare metal.
- Using the battery tester, measure individual cell voltages. Record all cell readings.
- Calculate max - min cell voltage. If > 50mV imbalance, flag in the SoH assessment.
- Check the battery indicator LED: 4 solid = 80-100%, 3 = 60-80%, 2 = 40-60%, 1 = 20-40%, blinking = <20%.
- Using the DJI app's battery health check, record the reported SoH percentage.
- If SoH < 80%, mark battery for replacement in TechMedix.
- Install replacement battery. Confirm correct orientation. Press until latch clicks (audible).
- Power on the T50 briefly to confirm battery detected correctly, then power off.
- Log battery swap in TechMedix: include SoH of removed battery, cell voltage readings, and replacement battery serial number.
Expected Outcomes:
- Battery removed and replaced without damage
- SoH assessment correctly categorized (serviceable / marginal / replace)
- TechMedix log entry complete with all cell voltage readings
Common Errors:
- Approaching propeller radius before confirming DISARMED state
- Misidentifying the battery orientation (T50 battery is asymmetric — only fits one way but technicians sometimes force it)
- Logging pack voltage instead of individual cell voltages
Assessor Sign-off Criteria: Safe procedure throughout. Battery correctly assessed. TechMedix log complete with individual cell data.
Lab 3: Log a P2 Alert and Escalation Workflow in TechMedix
Objective: Respond to a simulated P2 alert in TechMedix, perform the appropriate field assessment, and correctly escalate to P1 when criteria are met.
Equipment Required:
- TechMedix technician account (training environment)
- Assessor with admin account (to inject simulated alert)
- Unitree G1 training unit
- Multimeter
Safety Prerequisites:
- Robot in training safe-stop mode
- No live battery required for this lab (robot can be powered down)
Procedure:
- Assessor injects a P2 alert: "Elevated knee joint temperature — right knee, 58C, trending up."
- Technician acknowledges the alert in TechMedix within the 24-hour SLA window (assessor confirms acknowledgment timestamp).
- Navigate to the robot profile and review the last 24 hours of telemetry for the right knee temperature signal.
- Document the trend: is temperature still rising, plateauing, or recovering?
- Physically inspect the right knee joint for external heat signs (housing warm to touch, discolored grease, unusual smell).
- Log findings: temperature reading trend, physical findings, actions taken.
- Assessor will then inject an escalation event: temperature crosses 70C threshold.
- Technician must reassign alert to P1, update work order priority, and initiate escalation to L2 (select from technician roster in TechMedix dispatch).
- Draft escalation notes: current findings, recommendation, urgency.
- Submit. Assessor reviews the escalation entry.
Expected Outcomes:
- Alert acknowledged within SLA window
- Telemetry trend correctly interpreted
- Escalation to P1 triggered at the correct threshold
- Escalation notes meet completeness standard
Common Errors:
- Escalating before threshold is met (jumping to P1 prematurely)
- Writing subjective cause in escalation notes ("motor burning up") rather than objective data
- Failing to include the temperature trend chart screenshot
Assessor Sign-off Criteria: SLA met. Alert correctly managed. Escalation triggered at correct threshold. Notes complete and objective.
Lab 4: Emergency Stop Activation and System Recovery
Objective: Practice E-stop activation in a simulated emergency and execute the recovery procedure correctly.
Equipment Required:
- Unitree G1 training unit (powered on, in standby)
- TechMedix technician account
- Timer (phone stopwatch)
Safety Prerequisites:
- Assessor positioned at secondary E-stop (if available)
- 3m clearance in all directions from the robot during powered operation
- Technician briefed on recovery procedure before starting
Procedure:
E-stop activation:
- With robot in standby (not moving), assessor announces a simulated emergency scenario.
- Technician activates hardwired E-stop. Timer starts on assessor's signal.
- Technician must reach E-stop within 5 seconds of signal (this simulates emergency response).
- Confirm E-stop engaged: robot should not respond to any commands.
- Attempt to move a joint manually — confirm no resistance from active motor (if motors properly killed).
- Note timestamp of E-stop activation in work order.
Recovery procedure: 7. Identify and resolve simulated fault (assessor provides fault scenario — e.g., "obstacle cleared"). 8. Confirm 3m clearance in all directions. 9. Release E-stop: twist and pull on button (or per platform-specific procedure). 10. Power cycle the robot via TechMedix dispatch interface. 11. Wait for boot sequence to complete (Unitree G1: approximately 45 seconds to standby-ready). 12. Verify TechMedix shows the robot online and no residual fault codes. 13. Log the E-stop event: timestamp, scenario, recovery actions, confirmation of normal state.
Expected Outcomes:
- E-stop engaged within 5 seconds
- Recovery procedure completed without skipping steps
- Log entry complete
Common Errors:
- Releasing E-stop before clearing the fault cause
- Skipping the 3m clearance check before power-on
- Not logging the E-stop event (all E-stop activations require a log entry, even if no damage occurred)
Assessor Sign-off Criteria: E-stop response time under 5 seconds. Recovery procedure completed correctly. Event logged.
Lab 5: Complete a Work Order End-to-End
Objective: Complete an entire work order from dispatch acceptance through field service and final submission, using TechMedix.
Equipment Required:
- TechMedix technician account
- Unitree G1 training unit
- Full inspection toolkit (flashlight, multimeter, camera)
- Assessor with dispatcher account (to create and assign the work order)
Safety Prerequisites:
- Standard LOTO as per Lab 1
Procedure:
- Assessor creates and assigns a work order: "Scheduled maintenance inspection — Unitree G1, Unit G1-TX-001."
- Technician accepts the work order in TechMedix mobile interface. Note acceptance timestamp.
- Navigate to the site (simulated — within the training area).
- On arrival: update work order status to "Onsite" in TechMedix. Log GPS location.
- Perform full L1 visual inspection (as per Lab 1). Assessor will have configured 1-2 defects.
- Log all findings in the work order findings field (objective descriptions only).
- Take and upload all required photos: PRE_SERVICE, POST_SERVICE, and one per defect found.
- Complete battery SoH check and log results.
- For any defect requiring escalation, initiate the escalation workflow within TechMedix before closing.
- Mark work order status to "Complete."
- Submit work order.
- Assessor reviews submitted work order for completeness.
Expected Outcomes:
- Work order accepted, updated, and submitted within the same session
- All defects found and documented
- All required photos uploaded with correct naming convention
- Escalation triggered if any defect exceeds L1 resolution threshold
Common Errors:
- Forgetting to update status to "Onsite" on arrival (this is used for SLA tracking)
- Submitting work order before escalation is initiated (escalation should be complete or acknowledged before submission)
- Photo file names not following convention
Assessor Sign-off Criteria: Work order submitted with all required fields. All defects documented. Escalation workflow correctly used if applicable. No safety violations during the lab.